Introduction to cavitation and installation height of centrifugal pumps

First, the cavitation phenomenon of the centrifugal pump The cavitation phenomenon of the centrifugal pump means that the liquid to be delivered is partially vaporized due to the pressure of the saturated vapor at the delivery temperature equal to or lower than the pressure at the inlet of the pump (actually at the inlet of the blade), causing the pump Noise and vibration are generated. In severe cases, the flow rate, head pressure and efficiency of the pump are significantly reduced. Obviously, cavitation is not allowed in the normal operation of the centrifugal pump. The key to avoiding cavitation is that the pump should be installed at the correct height, especially when transporting volatile liquids with high temperatures.

Second, the installation height of the centrifugal pump Hg

Allowing the suction vacuum height Hs means that the pressure p1 at the pump inlet can be allowed to reach a large vacuum degree, and the actual allowable vacuum height Hs value is not a value calculated according to the formula, but a value determined experimentally by the pump manufacturer. This value is attached to the pump sample for user review. It should be noted that the Hs value given in the pump sample is the value when the water is used as the working medium, the operating conditions are 20 ° C and the pressure is 1.013 × 105 Pa. When the operating conditions and working medium are different, the conversion is required.

(1) Conveying clean water, but the operating conditions are different from the experimental conditions, and Hs1=Hs+(Ha-10.33)-(HÏ…-0.24) can be converted according to the following formula:

(2) Conveying other liquids When the conditions of the liquid to be transported and the villain are different from the experimental conditions, a two-step conversion is required: * step according to the above formula will be Hs1 detected by the pump sample; second step will be converted according to the following formula: Hs1 Into H?s

2 NPSH Δh

For the oil pump, calculate the installation height with the NPSH Δh, that is, use the NPSH Δh to be taken from the oil pump sample, and the value is also measured with 20 ° C water. If other liquids are transported, corrections are also required. Check the relevant books.

From a safety point of view, the actual installation height of the pump should be less than the calculated value. Also, when the calculated Hg is negative, it indicates that the suction port position of the pump should be below the liquid level of the sump.

Example 2-3 A centrifugal pump was found from the sample to allow the vacuum height Hs = 5.7 m. It is known that the total resistance of the suction line is 1.5 mH2O, the local atmospheric pressure is 9.81 x 104 Pa, and the dynamic head of the liquid in the suction line is negligible. Trial calculation:

(1) Installation of the pump when conveying water at 20 ° C;

(2) The installation height of the pump when the water is transported at 80 °C.

Solution: (1) The installation height of the pump is known to deliver 20°C clean water: Hs=5.7m

Hf0-1=1.5m

U12/2g≈0

The local atmospheric pressure is 9.81×104Pa, which is basically consistent with the experimental conditions when the pump is shipped, so the installation height of the pump is Hg=5.7-0-1.5=4.2m.

(2) When the 80 °C water is transported when transporting water at 80 °C, the installation height cannot be directly calculated by using the Hs value in the pump sample. The Hs should be converted according to the following formula, ie Hs1=Hs+(Ha-10.33) -(Hυ-0.24)

It is known that Ha = 9.81 × 104 Pa ≈ 10 mH 2 O, and the saturated vapor pressure of water at 80 ° C was found to be 47.4 kPa by the appendix.

Hv=47.4×103Pa=4.83mH2O

Hs1=5.7+10-10.33-4.83+0.24=0.78m

Substituting the Hs1 value into the formula to obtain the installation height Hg=Hs1-Hf0-1=0.78-1.5=-0.72m

Hg is a negative value, indicating that the pump should be installed below the pool level, at least 0.72m below the liquid level.

Serum Bottle

Culture base bottles are manufactured by high quality PETG materials and automated equipment, with high transparency and high utility. This product is applied to long-term storage of aqueous solutions, such as serum, medium, pancreatic enzymes, reagents, and more.

Bottle material: PET, cap material: HDPE bottle with precise scale

Bottle is a manner, easy to hold, keep storage and transportation
125ml, 250ml, 500ml, 1000ml
After strict leak test, make sure no leakage
No DNA / RNA enzyme, no thermal, non-toxin resistant low temperature -135 ° C freezing storage

After electroless beam irradiation.


01

Serum Bottle,125Ml Serum Bottle,Hdpe Serum Bottle,1000Ml Serum Bottle

Jiangsu iiLO Biotechnology Co., Ltd. , https://www.iilogene.com